ruskin dampers. (2 kPa). ruskin dampers

 
 (2 kPa)ruskin dampers  Mounting Angle Fasteners Sleeve: #10 bo lts or screws, 3/16" (5) steel rivets or 1/2" (13) long welds

Ruskin Literature. Dampers shall be Ruskin Swartwout Series Model 914 FRP control dampers. Consult Ruskin or your Ruskin representative when damper is to be applied in conditions exceeding rec-ommended maximums. Access Doors. Masonry Wall or Floor: #10 self-tapping concrete screws Wood/ Steel Stud Wall. SUGGESTED SPECIFICATION 3900 Doctor Greaves Road Grandview, MO 64030 Website: AUTHORITY IN AIR CONTROL Phone: (816) 761-7476 Document Title O & M for Commercial Control Dampers Limited Warranty Document LINKS TO IMPORTANT. Combination louvers can incorporate both drainable and non-drainable blades which are selected based on the structure. Ruskin blast suppression dampers have been designed for peak reflective pressures from 1. Dampers can be constructed of galvanized, stainless, or. com. It also features: Frame corners that are internally braced to reduce racking. Fire dampers with 11/2 or 3 hour ratings for walls or floors are not to be used in fire rated ceiling openings. > Case Studies. EFL or PFL heat-actuated devices that permit closed closure through the actuator and are automatic remote resettable after test, smoke detection, or power. Our plant in Thailand is well-equipped to manufacture next-generation products. They are designed to be installed inside duct work rather than flange mounted. Multi-section dampers typically use jackshafts to link sections together. CFDR7T - 2"x4" Truss Assemblies (Ref. 500. Ruskin’s Information is not a. g. Website: AUTHORITY IN AIR CONTROL Phone: (816) 761-7476. angles together at corners of dampers. Dampers furnished actual size. Mounting Angle Fastener Spacingon dampers with v-groove blades, we recommend sizing dampers for 1,500 fpm. Ruskin’s optional wireless damper Inspector™ , utilizing wireless communication protocol by EnOcean®, is the ideal solution for mandatory testing of motorized life safety dampers per NFPA* and Building Code requirements. — Ruskin ® announces three new emergency generator inlet dampers (GenSet) designed to quickly open to relieve combustion air. g. Pressure Relief Doors. Industrial Multi-Blade Control Damper. - Damper/sleeve assembly furnished actual size to inside of sleeve. Some of the approved ceiling designs are L501,. The CD60CE in 316 stainless steel construction offers superior corrosion resistance and. Noise Control. V Groove & Single Blades. The commercial dampers provide low pressure openings with exceptional pressure drop performance, while the industrial line includes heavier gauge materials to. g. 3900 Dr. Masonry Wall or Floor: #10 s elf-tapping concrete screws Wood/Steel Stud Wall: #10 screws. wg) Operator Submittal Installation Instructions CSI Specs Drawings PDF DWG Automatic Balancing Dampers ABD Thermoplastic Round 8 425 cfm 2 - ABD-RB Thermoplastic Round 8 425 cfm 2 - ABD-T Thermoplastic Round 8 425 cfm 2 - ABD-FD Thermoplastic Round/Curtain 6 275 cfm 2 - . Ruskin Headquarters are located in the Southeastern portion of the Greater Kansas City Metropolitan area Mailing Address: Ruskin Company 3900 Dr. Home; PRODUCTS Air Control and Backdraft Dampers Ceiling Radiation Dampers. (2 kPa). pressure) for 15 minutes. g. The webpage also includes diagrams, dimensions, and performance data of the dampers, as well as installation and maintenance instructions. Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. Commercial dampers provide low-pressure openings with excellent pressure-drop performance. ©Ruskin October 2007 ® Spec FSD60-C-1007/Replaces FSD60/36-C-1206 APPLICATION The FSD60-C is two dampers in one. The FD35/OW, FD35SS/OW and FD60/OW static fire dampers are for use in static (fans off) systems only. Corrosion. The Ruskin Company’s (hereinafter “Ruskin”) content, functionality and product information provided in this data file, including Ruskin design and dimensions (collectively referred to herein as “Ruskin’s Information”) are offered solely to you as a convenience and are for your information only. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural Gallery; FAQs. Static pressure and CFM are corrected to. g. Our line of outside air dampers are available in 0% - 35% range or 0% - 100% range, and all are easy to install with factory-provided plugs. G Bolt Circle Diam. “Out Of Wall” Grille Access Fire Dampers 1 1/2 Hour UL555 Rated | For Dynamic & Static Systems DIBD2GA are dynamic fire dampers designed for “out of wall” applications. Figure 5. Deflections in other damper widths (less than 48" [1219]) at Smoke dampers are UL555S tested and labeled, low leak damper and actuator assemblies constructed to restrict the spread of smoke in HVAC systems that are designed to be automatically shut down in the event of a fire, or opened to control the movement of smoke within a building when the HVAC system is part of an engineered smoke control system. INSTALLATION Install with frame square without twisting or racking. g. The ELBD375I Automatic Intake Dual Combination aluminum louver combines a drainable blade louver and an intake backdraft damper in a nominal 9" frame depth. Dampers may tolerate higher pressures and velocities than those listed here. For some applications, it is essential that thermal conductivity be kept at a minimum. 1. Keywords: Ruskin, Commercial, backdraft, damper S3G, Data, Submittal, galvanized, steel Created Date: 1/5/2017 12:58:19 PMRUSKIN finishes enhance product appearance to blend with other colors selected. > Case Studies. Find the conversion velocity (CV) by multiplying the selected size damper's area factor by the flow rate in CFM: CV = Area Factor x CFM. AMCA licensed as a class 1A damper. ) SUGGESTED SPECIFICATION STATIC PRESSURE (Inches Water Gage) AIR FLOW IN C. 2. Consult Ruskin or your Ruskin repre-sentative when damper is to be applied in conditions exceeding recommended maximums. (2) 1/4-20 Nuts 2. DIMENSIONAL DETAILS SUGGESTED SPECIFICATION 3900 Dr Greaves Rd. Sizes to fit round openings up to 20" diameter and rectangular openings up to 24" x 24" are available. Higher velocities are not recommended for outside air openings, due to water penetration concerns. Ruskin model CD50IF offers HVAC design engineers an ultra-low leak high performance damper which provides: AMCA Class 1A leakage for energy savings Integral 1 ½” flange (front or rear) Mechanically fastened blade edge seals for longevity Shake proof linkage for low maintenance. Rectangular Silencers. The CBD2 is an extremely sensitive gravity operated backdraft damper. Unless specifically ordered otherwise, when looking at the concealed linkage side of the damper and the bottom blade turnsA. Louver Paint Finishes - Color Guide. Ruskin CD60DC is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the jackshaft side. 7 %âãÏÓ 69 0 obj > endobj xref 69 77 0000000016 00000 n 0000002434 00000 n 0000002561 00000 n 0000004375 00000 n 0000004685 00000 n 0000005201 00000 n 0000005701 00000 n 0000006313 00000 n 0000006746 00000 n 0000007307 00000 n 0000007930 00000 n 0000007966 00000 n 0000008506 00000 n 0000008619 00000 n. Equipped with linkage out of the airstream. DAMPER SIZES Understanding damper leakage rates and leakage classes enables specifiers, contractors, and building owners to identify the correct damper products. Each has added features that enable them to meet all high temperature, high pressure airflow modulation and shutoff. 3 m/s) and 8” w. It features: UL555S Class I leakage class. 2. The barometric bypass dampers relieve excess air in duct systems through the use of a counter-balanced controlled arm weight. Damper Maximum Size Velocity (FPM) Pressure (in. Ruskin Control Dampers and Backdraft Dampers Get the air where you want it — when you want it! 3 CD60 Ultra Low Leakage Damper The CD60 damper is a “true” airfoil blade damper designed for medium to high velocity and. Ruskin model TED50XT offers HVAC design engineers an ultra-low leak thermally efficient damper which provides: • Energy savings for building owners • Effective resistance to condensation in climate prone areas. Butterfly blade. The ELBD375E Automatic Exhaust Dual Combination aluminum louver combines a drainable blade louver and an exhaust backdraft damper in a nominal 6” frame depth. The Ruskin ® knowledgeable and dedicated rep network adds value by listening to customer’s needs and providing expert advice and nimble service. Damper shall be equivalent to Ruskin model ARD25. g. The damper is rated for Ruskin CD50DC is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the jackshaft side. The pressure drop is the point at which the horizontal,. Life Safety Products; Louver and Architectural; Louver Paint Finishes - Color Guide; Diffusers; Energy Recovery Ventilators; Commercial Control DampersRuskin - Dampers Louvers (816) 761-7476 Subject: The FSD60FA is a combination fire/smoke damper that allows through the grille access to the damper, actuator and heat actuated device. Ruskin offers blast suppression dampers which are custom designed to each application. @ 1" w. The DIBD20, 40, 60 carry a 1 1/2 hour UL fire damper label and are classified as a dynamic damper for use in HVAC systems that remain in operation during a fire. Dampers may tolerate higher pressures and velocities than those listed here. DAMPER SIZESRuskin CD60 Commercial Control Dampers Type for a low price! Get free shipping on orders over $999!. A complete line of damper products for fire and smoke control in life safety systems and for airflow control in commercial HVAC and industrial systems. Built from strong materials and designed on state-of-the-art equipment, Ruskin Industrial Control Dampers are perfect for demanding conditions. Galvanized Steel Airfoil Blades. When you need to "dial in" branch air flow, Ruskin Model VFBD35 Value Flo "IRIS" Balancing Damper is well suited for ease of installation and labor savings. The foregoing limited warranty does not apply to (i) consumable products and components (e. When Ruskin’s Fire/Smoke Dampers are supplied with a factory installed damper sleeve, the sealed. Ruskin model CD50 offers HVAC design engineers an ultra-low leak high performance damper which provides; • Energy savings for building owners • Low noise generation and lowest pressure drop • Low maintenance. DaMpER aSSEMBliES The MD35 is intended to be self supporting only in its largest single section size. Specifier select damper shall have SPC field-adjustable static-pressure control to maintain pressures in ranges from . be-csd-thailand@jci. SP200 Switch Package to allow remote indication of damper blade position. and a maximum of 3 CFM sq. To provide even greater control of dampers in HVAC systems, Ruskin also. Fewer parts, fasteners, and assembly processes ensure years of sustainable performance in heavy duty applications. 3. g. Ruskin fire/smoke dampers. PRESSURE DROP INFORMATION Performance curves based on AMCA Standard 500 using test setup apparatus figure 5. Access Doors. Commercial Dampers. Greaves Rd. Ruskin ® Terms and Conditions for more information. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowRuskin - Dampers Louvers (816) 761-7476 Subject: The FSD35 is a combination fire and smoke damper designed with triple V-groove blades and controlled closure technology that provides point-of-origin fire containment and operational flexibility in static and dynamic smoke management systems. Ceiling Fire Dampers UL Classified Radiation Dampers for Wood Joist Construction The CFD7 is a UL Classified Ceiling Fire Damper that is UL approved for installation in ceilings constructed from wood joists. 56 psi and 38. Note: Multiple section dampers are not intended to. All calculations are with external mounted actuators and accessories. a. Reinforcing plates are not required for assemblies consist-ing of two dampers attached end-to-end or three dampers attached side-to-side as depicted in figure 3. These same finishes provide extended weathering resistance similar to adjacent building surfaces. It features: Accurate airflow and isolation at extreme elevated temperatures. Torque applied holding damper closed at 10 in. Dampers shall be in all respects equivalent to Ruskin model CBD6. Inspiring the industry with thought provoking, revolutionary ideas, Ruskin airfoil blade dampers comprise the only damper design incorporating a single piece roll-formed frame and blade. Welcome to Ruskin Rooftop Systems 972. These UL Classified dampers protect against heat, as well as flame, in ceilings with fire resistance ratings of 3 hours or less. It features a galvanized steel frame, single skin blades, and a variety of actuator options. • Sealing durability in. Johnson Controls offers a broad range of HVAC dampers and louvers engineered to fit your unique application and size requirements. Commercial Dampers; Diffusers; Economizers; Energy Recovery Ventilators; Industrial Dampers; Life Safety Dampers; Louvers & Architectural; Pressure Relief Doors; Noise. Ruskin September 2021 Page4 CONSTRUCTION & DIMENSIONAL INFORMATION Ruskin CD50GS is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the. It features: 750 degree F standard temperature rating! A variety of applications in air and material volume control systems. Catalog. Hexagonal axles that ensure a positive lock with blades. ft. Damper locks together without bolts, screws, or. Specifier Select Option Dampers shall be equipped with factory installed damper. Rep Login (817) 509-2300 [email protected] you are looking for a thermally efficient damper that can reduce energy costs and prevent condensation problems, you may want to check out the Ruskin model TED50. Our History. If the actuator must be mounted on top or bottom, select the FSD60V. Ruskin FDR25 is a true round fire damper designed for use in fire rated walls and floors and is the perfect choice when using round duct. Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. To determine the pressure drop: 1. six plant locations, Ruskin is meeting the needs of contractors and engineers around the globe. Damper Width “A” Dimension in inches (mm) » Tunnel Fire Dampers DISCLAIMER: The Ruskin® brand’s (hereinafter “Ruskin”) content, functionality and product information provided in this data file, including Ruskin design and dimensions (collectively referred to herein as “Ruskin’s Information”) are offered solely to you as a convenience and are for your information only. Kansas City, MO 64030 (816) 761 -7476 FAX (816) 765 -8955 L = Diameter + 2 inches (51) "D" Diameter 3. Linkage shall be concealed, out of airstream, within the damper frame to reduce pressure drop and noise. or N. Ruskin round and oval solutions are perfect for applications utilizing spiral duct, or transitioning from rectangular to round. The industrial grade backdraft dampers offer rugged construction and heavy gage materials to withstand the high velocities and back. Spec AIRFLOW-IQ-0121 STATD SPTS R ST T TT T R T. The CD51 Control Damper has a 5" frame. at corners of dampers. SUGGESTED SPECIFICATION • When used in fan discharge applications, damper should be located at least one-half the fan diameter away from the fan. 7476 Fax: 816. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 ® Nominal Diameter, Inches Total CFM. 1/4” cfm at 4” w. 2. Installation Instructions FSD60FA, FSD36FA, and FSD60FA-M Front Access Combination Fire & Smoke Damper 11/2 HOUR UL555 & UL555S CLASS I OR CLASS II CLASSIFIED RATING Author: Ruskin - Dampers Louvers (816) 761-7476 Subject: Models FSD60FA, FSD60FA-M, and FSD36FA combination fire/ smoke dampers are. Airfoil blades, which. Easy installation. ft. Ruskin - Dampers Louvers (816) 761-7476 Subject: The FSD35 is a combination fire and smoke damper designed with triple V-groove blades and controlled closure technology that provides point-of-origin fire containment and operational flexibility in static and dynamic smoke management systems. com W: Genset dampers are designed to provide maximum combustion air and pressure relief quickly for emergency generator start up to avoid damage of equipment or surrounding space. Ruskin Literature. Ruskin Literature. for dampers up to 17. Determine area factor for damper by entering the Area Factor Table through duct width and height. into damper blade and not a secondary operation. Frame shall be 16 ga. FACE and BYPASS MIXING DAMPERS Dampers larger than maximum single section are an assembly of equal size single section dampers (maximum section size 48"w x 72"h (1219 x 1829) and may be coupled for operation in a variety of ways. g. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowThe FSD60V Combination Fire/Smoke Damper is both UL555 and UL555S Classified. As an option, qualification for use in Nuclear. , Ltd. The damper/actuator assembly is exposed to elevated temperatures for 30 minutes and then immediately cycled three times. • Fire smoke dampers larger than single section may require multiple actuators. Ceiling fire dampers, also known as "Radiation" dampers, are designed and tested to limit the radiant heat transfer through an air inlet/outlet opening in the ceiling membrane of a fire resistance rated floor/ceiling or. UL approval for dual directional air flow. Standard features vary by model to. pivot pins. 8) steel. (1 kPa) static pressure and shall be tested and rated to close with airflow in either direction. Industrial Fiberglass Louvers. Share this page: Guillotine "fire damper" fabricated from a fire resistant panel used in the construction of 3 hour UL tested and labeled sliding fire doors. See “Smoke Damper Multiple Section Detail” spec sheet for details. Ruskin July 2020 Page1 CD60DC (DATA CENTER) High-performance Galvanized Steel Airfoil Blade Damper AMCA Class IA Leakage Rated The CD60DC is designed for HVAC systems serving data center facilities where high performance and reliability is expected. back pressure depending on damper size. Each fire damper shall be labeled for use in dynamic systems. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowIBD2G, IBD2SSG (Static) and DIBD2G, DIBD2SSG (Dynamic) curtain type fire dampers for grille installation may be installed vertically in walls or horizontally in floors with fire resistance ratings of less than 3 hours. 5 21w ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. 3. From light operations to heavy-duty industrial applications and from backdraft control to indoor air quality control, Ruskin provides the perfect control damper. All (D)IBD Curtain Type Fire Dampers Excluding IBDT Series model – FLIB fd fuse link assembly 1. UL555S rating up to 350°F (177°C). Curtain Type Static Fire Dampers 1 1/2 Hour UL555 Rated For Use In Static System Ruskin Model IBD20, 40, and 60 are 1 1/2 hour UL classified static (fans off) curtain style fire dampers for use in HVAC systems that shut down during a fire event. The DTS gives maintenance personnel the ability to “cycle test” the fire/smoke damper by pushing and holding the button until the damper has cycled. Industrial Multi-Blade Control Damper. Maximum 8" static pressure. When used in fan discharge applications, damper should be located at least one-half the fan diameter away from the fan. The Ruskin® Portfolio of life safety solutions offers more than 70 models of 1½ hour rated fire dampers and combination fire/smoke dampers that can be used with. Unlike other ceiling. See “Combination Fire Smoke Damper Multiple Section Detail” specPerfect for a Wide Variety of Applications. O. Ruskin is a leading manufacturer of dampers, louvers, air measuring, noise control and energy recovery products for various applications. Damper shall be Ruskin model CDRS82. This model offers the lowest AMCA leakageRuskin® is an authority in Air Distribution and Air Control products such as dampers, louvers and silencers. 5" w. It features: Fire and heat protection where HVAC components penetrate the ceiling membrane. Model ZCRD25 can also be supplied with Ruskin Cable drive systems. We are the leading manufacturer of air. The CDRS15 is a true round commercial control damper that installs easily in round spiral ductwork. Hours: 9am - 5pm CDT M-F. The ARD25 is. com. g. 5 hr. Zone Control. a. Ruskin is a leading manufacturer of dampers, louvers, air measuring, noise control and energy recovery products for various applications. TION 1. Multiple section damper assemblies may require brac - ing to support the weight of the assembly and to hold against sys - tem pressure. 765. The switch package shall include two position indicator switches linked directly to the damper blade to provide full open and full closed damper blade position. Constructed with durable galvanized steel. Closes and locks the damper via a standard replaceable fuse link when the specified temperature is is detected. Pressure Relief Doors. Certain actuators in Table 1 are UL Recognized Components under. Most F/Cs andSMOKE & COMBINATION FIRE SMOKE DAMPER ACTUATORS. Built from strong materials and designed on state-of-the-art equipment, they are perfect for demanding conditions. Greaves Rd. Damper shall be, in all respects, equivalent to Ruskin model BD2A2. Location of Damper in Ductwork Smoke Dampers must be placed in the ductwork so the closed blades are within 24” (610) of the smoke barrier and before any duct inlets or outlets (access doors not included). FILES (0) Share this page: Ruskin's Automatic Balancing Dampers provide a reliable way to maintain constant airflow volume and occupant comfort in high-rise buildings. Backdraft blades are . static pressure. The damper frames are made of galvanized steel in a channel frame construction, offering an equivalent 13-gauge metal strength. L586) Ceiling fire dampers maintain the integrity of fire resistive ceiling assemblies constructed from wood True Round Grille or through ceiling membrane penetrationRuskin February 222 Page 1 FDR25 Galvanized Steel True Round Fire Damper 1 1/2 Hour UL555 Rating for use in Dynamic & Static Systems Ruskin FDR25 is a true round fire damper designed for use in fire rated walls and floors in either Static or Dynamic systems. Spec vFBD35-818/Replaces VFBD35-708 ©Ruskin August 2018 • 3900 Dr. The DIBD20, 40, 60 carry a 1 1/2 hour UL fire damper label and are classified as a dynamic damper for use in HVAC systems that remain in operation during a fire. a. All Ruskin fire smoke dampers meet or exceed the minimum UL555S requirements. FILES (0) Share this page: 1. for dampers up to 6 sq. 3 m/s) and 8” w. The damper is rated for maximum velocity of 2,000 fpm (10. Dampers above 18" (457) – 10 gage steel (3. Dampers can be constructed of galvanized, stainless, or aluminum and are available with a diverse compliment of. Dampers shall be designed for maximum 1500 fpm spot velocities and up to 4" w. Fiberglass Dampers. CFD7T - 2"x4" Truss Assemblies (Ref. The EFL closes and locks the damper when temperatures exceed 165°F (74°C)Ruskin FDR25SS is a true round fire damper designed for use in fire rated walls and floors and is the perfect choice when using round duct. Learn more about the features, specifications and dimensions of the PVC12 damper from Ruskin, the leading manufacturer of air control. The webpage provides the specifications and features of the Ruskin® CD80AF1 and CD80AF2 industrial control dampers, which are designed for heavy duty applications and high temperature environments. Combination Fire/Smoke Damper UL555 and UL555S Leakage Class 1 Classified The FSDR60 is a true round, Class 1 leakage rated combination fire/smoke damper designed for use in metal, wood, or concrete fire and smoke rated partitions and. pivot pins. Standard features vary by model to make application selection straightforward. g. The damper ships with a factory mounted and commissioned 24 VAC, spring return actuator set to power closed and spring or "fail" open. Static pressure and CFM are corrected to . These UL Classified dampers protect against heat, as well as flame, in ceilings with fire resistance ratings of 3 hours or less. Ruskin’s smoke dampers are UL555S labeled with either electric or pneumatic actuators mounted internal (in air stream) or external (out of air stream). See “Smoke Damper Multiple Section Detail” spec sheet for details. Ruskin model SD50 offers HVAC design engineers an ultra-low leak high performance Leakage Class I smoke damper which provides: • Barrier to stop smoke • Lowest pressure drop for energy savings • Optional fail open operation for smoke exhaust applications • Highest dynamic closure rating of 4,000fpm & 8” static pressure. It features: • Galvanized steel construction • Class II leakage rating • Low torque operationequal to the damper width of two or more adjoining damper sec-tions. 01" w. Ruskin manufactures a complete line of louver models available for both standard and special needs, such as high-volume airflow, wind driven rain, special architectural shapes, sight proof. Title: CDRS82- Spec Author: Ruskin Created Date:The CFDR7T is UL555C Classified Ceiling Fire Damper for wood construction. From dampers and louvers, to air measuring systems and ERVs, Ruskin ® is recognized for consistent innovation, engineering excellence and precision manufacturing. FILES (0) Share this page: Constructed of premium vinyl ester resins, Ruskin’s fiberglass airflow control products are ideal for installations in corrosive environments such as waste water treatment, micro-electronics fabrication, pulp and paper mills, air pollution control systems and corrosion resistant air exhaust and. emergency, dampers and their actuators alike may be required to operate at elevated temperatures. SUGGESTED SPECIFICATION 3900 Doctor Greaves Road Grandview, MO 64030 Website: AUTHORITY IN AIR CONTROL. Built from strong materials and designed on state-of-the-art. , Ruskin does not recommend using these designs in systems with velocities greater than 2000 fpm. g. Issue ‘E’ Fuse Link 4. Must be installed in the factory. Our dampers are ideal for outdoor air applications that require low leakage or heavy duty industrial needs to prevent hot or cold outside air penetrating your building. Dampers shall incorporate a dish-shaped circular blade mounted to internal slide-Ruskin CD450 is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the jackshaft side. 761. Ruskin provides a wide variety of actuators and other accessories to customize our dampers in order to meet your needs. Multiple section dampers are available in unlimited sizes. g. Ruskin's all aluminum damper for medium and low pressure commercial HVAC systems offers low leakage with a stan-dard, commercial built damper. rectangular, airfoil, class IA leakage, heavy duty, 6000 FPM, 13" w. Maximum rating of 4,000 fpm and 8" w. Learn about the features, specifications and benefits of different series of Ruskin products, such as TDP05K, CD60, CD50, CD40,. And with Ruskin Expressthese labor saving fire dampers can be shipped tomorrow! FAST Angle One Side Dampers are available in sizes and styles that meet your specific job requirements. Static only damper labels are not permissible. lbs. 2 m/s) and 4” w. The DIBD2/OW can be installed on either side of the wall or top or bottom side of the floor. Fiberglass Series round backdraft dampers. Look for the AMCA Labeled products to be sure you are getting the performance you require. The majority of designs are rated at 2 or 3 hours. The Quick Product Selection Reference Guide assists in selecting the appropriate Ruskin® Product for your application. Louvers & Architectural. Autodesk®Revit® is Building Information Modeling (BIM) at its best. Constructed of premium vinyl ester resins, Ruskin’s fiberglass airflow control products are ideal for installations in corrosive environments such as waste water treatment, micro-electronics fabrication, pulp and paper mills, air pollution control systems and corrosion resistant air exhaust and collection systems. It features: Airfoil blades, which have greater strength, less static pressure, superior sealing ability, superior fire protection ability and produce less noise. 1. of 8. They also offer a new coupler option that joins two damper sections without a jackshaft allowing an actuator to be mounted on side of frame to provide a narrow profile when space is limited. Dampers shall be in all respects equivalent to Ruskin model IL35. 2. Ruskin Headquarters are located in the Southeastern portion of the Greater Kansas City Metropolitan area Mailing Address: Ruskin Company 3900 Dr. per sq. H. Fiberglass Backdraft Dampers. Shims should be used between damper frame and opening or duct to. 2) wall thickness with 12 gage (2. specification but their recommendedThe ZMD60 Zone Mixing Damper is suitable for multiple zone applications where high performance is required. Multiple velocity and temperature points on one or more probes installed in the duct or plenum are averaged to arrive at air measurements. Ruskin’s adjustable louvers and louver/damper combinations allow our customers to enjoy the benefit of architectural styling with air control and shut off. Masonry/Wall or Floor: #10 self-tapping concrete screws. From light operations to heavy-duty industrial applications, Ruskin provides the perfect backdraft damper. (2) ‘E’ Clips 3. g. Greaves Road Grandview MO 64030 Phone: 816-761-7476 ruskin@ruskin. 7447 Toll Free: 800. the damper/sleeve. It features: Corrosion resistant backdraft protection from its stainless steel construction. Spec FSDGA-216/Replaces FSDGA-1115 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. Maximum velocity for V-Groove blade 2000 FPM and Airfoil blades 3000 FPM. It is rated as a 1-1/2 hour fire damper and a Leakage Class II Smoke damper. Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) lo ng welds. a. 6 Pneumatic Damper Actuator is recommended for control of outdoor, return air, exhaust, face and bypass, and fan discharge dampers. 2 and can be equipped with factory-mounted actuators. Sizes to fit round openings up to 20" diameter and rectangular openings up to 24" x 24" are available. 75" w. It is also: Flange mounted. Airfoil blades, which have greater strength, less static pressure, superior sealing. upstream of the damper. Life Safety Products. Learn more about the FSD60 and its installation. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowRuskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. 081" thick extruded aluminum at approximately 4" c-c spacing. For up-to-date information visit CFD . Pressure Relief Doors. FILES (0) Share this page: Trusted for decades, Ruskin V-Groove blade dampers were designed to extend a lower cost solution for standard duty (medium or low pressure) applications. 2. Dampers shall be in all respects equivalent to Ruskin Model CD50CE. Linkage shall be concealed, out of airstream, within the damper frame to reduce pressure drop and noise. 350° Vertical or Horizontal SIze StAtIC PReSSURe teMPeRAtURe INStALLAtIoN ACtUAtoR ReqUIReMeNtS * UL555S requires that all. Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. Galvanized Steel V-Groove Blades. Mounting angles must overlap the partition a minimum of 1" (25). Ruskin fire dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. Leakage information based on pressure differential of 1" w. ft. Greaves Rd. Multi-section dampers typically use jackshafts to link sections together. Horizontal dampers installed in walls and floors shall have extended dynamic closure and operational ratings of 4000 fpm (20. All data has been cor- Dampers 18" (457) and under – 12 gage steel (2. Model ‘G’ curtain fire dampers are offset. Space fasteners 6" (152) on center and a maximum 2" (51) from the ends of the joining sec-tions or from each corner. Ruskin FAST and PFMA are 20 guage steel mounting angles designed and approved for use specifically with Ruskin fire and fire/smoke dampers. Greaves Rd.